Customization: | Available |
---|---|
Type: | Inductive Pressure Sensor |
Component: | Mechanical Structure Type |
Still deciding? Get samples of US$ 1/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Melt Pressure Transmitters
ME Series
The ME series are pressure transmitters for using in High temperature environment. The main characteristic of this series is the capability to read temperature of the media up to 400°C. The constructive principle is based on the hydraulic trasmission of the pressure. The fluid-filled system assures the temperature stability. The phisical measure is transformed in a electrical measure by means the strain-gauge technology.
• Pressure ranges from: 0-35 to 0-2000 bar / 0-500 to 0-30000 psi
• Accuracy: <±0.25% FSO (H); <±0.5% FSO (M)
• Fluid-filled system for temperature stability
• Mercury filling volume: ME0 (30mm3 ); ME1, ME2, ME3 (40mm3 )
• 1/2-20UNF, M18x1.5 standard threads; other types available on request
• Autozero function on board / external option
• Drift Autocompensation function (SP version)
• Standard diaphragm is 15-5 PH stainless steel with GTP coating
• 17-7 PH corrugated diaphragm with GTP coating for ranges below 100bar-1500psi
GTP (advanced protection): Coating with high resistance against corrosion, abrasion and high temperature
Accuracy (1) | H <±0.25%FSO (100...2000 bar) M <±0.5%FSO (35...2000 bar) |
Resolution | Infinite |
Measurement range | 0..35 to 0..2000bar 0..500 to 0..30000psi |
Maximum overpressure (without degrading performances) |
2 x FS 1.5 x FS above1000bar/15000psi |
Measurement principle | Extensimetric |
Power supply | 10...30Vdc |
Maximum current absorption | 32mA |
Insulation resistance (at 50Vdc) | >1000 MOhm |
Output signal Full Scale (FSO) | 20mA |
Zero balance (tollerance ± 0.25% FSO) |
4mA |
Zero signals adjustment (tollerance ± 0.25% FSO) |
"Autozero" function |
Span adjustment within ± 5% FSO | See Manual |
Maximum allowed load | See diagram |
Response time (10...90% FSO) | ~ 1ms |
Output noise (RMS 10-400Hz) | < 0.025% FSO |
Calibration signal | Calibration signal |
Output short circuit ingress and reverse polarity protection | YES |
Compensated temperature range | 0...+85°C |
Operating temperature range | -30...+105°C |
Storage temperature range | -40...+125°C |
Thermal drift in compesated range: Zero / Calibration / Sensibility | < 0.02% FSO/°C |
Diaphragm maximum temperature | 400°C / 750°F |
Zero drift due to change in process temperature (zero) | < 0.02 bar/°C |
Zero drift temperature for Autocompensated version (SP) within the temperature range 20°C-400°C inclusive the drift temperature of the housing |
< 0.003 bar/°C 100 ≤ p < 500 bar 0.0014 %FS/°C p ≥ 500 bar |
Standard material in contact with process medium | Diaphragm: • 15-5 PH with GTP coating • 17-7 PH corrugated diaphragm with GTP coating for ranges <100 bar (1500psi) Stem: • 17-4 PH |
Thermocouple (model ME2) | STD : type "J" (isolated junction) |
Protection degree (with 6-pole female connector) | IP65 |